H/HL | Air Conditioning Units
frameless construction
casing strength D1, D2
casing air leakage L1, L2
thermal bridging TB2
thermal transmittance T3
easy operation and assembly
high design variability
Applications and Operating Conditions
The units are designed for central air distribution and comprehensive air treatment: from filtration, heating, and cooling to highly efficient heat recovery. They are utilized in industrial halls, administrative buildings, hospitals, shopping centers, and schools. The standard design guarantees reliable operation in outdoor temperatures ranging from -30 °C to +40 °C.
Construction
The sections are made of frameless sandwich panels. The panel casing consists of two 0.8 mm thick steel sheets, joined along the perimeter by single-sided rivets. The sheets can be galvanized, painted (RAL 9002 – ivory), or stainless steel, in various combinations for the outer and inner sides. Inside the panel is a mineral wool insulation with a bulk density of 50 kg/m³, fire resistance class A1. The panel thickness is 50 mm. The frameless construction ensures a perfectly clean interior space throughout the unit, thereby creating a hygienic design. Casing strength is ensured by two special joints, registered with the Industrial Property Office in the industrial design database.
Advantages of Frameless Construction
- excellent casing strength
- reduced heat transfer losses through the unit casing
- perfectly clean interior space
- shorter section lengths compared to frame-based modular units
- easy assembly and operation
- high variability of unit designs
- lower acquisition cost
H-Control Monitoring and Control System
The units can be equipped with the H-Control autonomous control system. This system can be easily operated via PC, a remote controller with an LCD display, a touchscreen controller, or a superior BMS system. The system enables:
- continuous fan speed control
- control and protection of the water heater
- control and protection of heat recovery exchangers
- control of shut-off, mixing, and bypass dampers
- heat pump compressor control including reverse cycle
- air filter clogging signaling
- fault signaling
Subgroups
H – Modular units (square cross-section)
- Air transport: Fans with free-running impellers and AC or EC motors
- Heating: water, electric, steam, gas
- Cooling: water, direct expansion (DX) evaporator
- Heat recovery: plate (cross-flow/counter-flow) exchanger, rotary exchanger, liquid-coupled exchangers
- Mixing
- Humidification
- Dehumidification
- Noise attenuation
- Filtration: bag filters, panel filters, grease filters, compact filters, HEPA filters, active carbon
Design: indoor, outdoor, hygienic, ATEX
HL – Modular units (rectangular cross-section)
- Air transport: Fans with free-running impellers and AC or EC motors
- Heating: water, electric, steam, gas
- Cooling: water, direct expansion (DX) evaporator
- Heat recovery: plate (cross-flow/counter-flow) exchanger, rotary exchanger, liquid-coupled exchangers
- Mixing
- Humidification
- Dehumidification
- Noise attenuation
- Filtration: bag filters, panel filters, grease filters, compact filters, HEPA filters, active carbon
Design: indoor, outdoor, hygienic, ATEX
H-BLOCK – Compact Solution
Utilizes an identical frameless construction, designed as a compact unit (Plug & Play) for rapid installation.
- Air transport: Fans with free-running impellers and AC or EC motors
- Heating: Hot water exchanger or electric
- Cooling: Water cooler or direct expansion (DX) evaporator
- Heat recovery: plate (cross-flow/counter-flow) exchanger or rotary exchanger
- Mixing
- Filtration: Bag filters class G4 to F7
Design: indoor
Product Documents
TP12105_4_EN – Assembly and operation manual (EN)
Product Data Sheet H/HL
TP12107_4_CZ – Assembly and operation manual H-Block (CZ)
Product Data Sheet H-Block

Comments are closed.